SİM Quickshingle (Rectangular-Square)
Patented SİM Quickshingle Rectangular (Square) provides…
SİM Quickshingle Rectangular (Square) – Patterned Membrane
SİM Quickshingle Rectangular (Square) (Patterned Membrane) is a patented waterproofing sheet that offers high performance and aesthetics. One surface is coated with colored minerals, and the other surface is covered with polyethylene film, making it suitable for self-patterned applications. The membrane is made from polymer bitumen and reinforced with polyester felt to enhance mechanical strength.
Features:
-
Pattern and Color Options: Classic (rounded), hexagonal (honeycomb), traditional, and rectangular (square)
-
Superior Waterproofing: Provides durable and long-lasting waterproofing
-
Professional Application: Suitable for industrial and roofing applications
Features – SİM Quickshingle Rectangular (Square)
-
Repeating Pattern Structure: The patterns repeat, providing a seamless and aesthetic appearance; application is fast.
-
Nail-Free Application: Applied by heating and bonding; ensures complete watertightness and reliable insulation.
-
Wide Climate Performance: Performs well in various climate conditions and is suitable for widespread applications.
-
Absolute Waterproofing: Its impermeable structure ensures reliable insulation.
-
Compatibility with Various Surfaces: Provides high-performance insulation on wooden, reinforced concrete, and metal roofs.
-
Excellent Adhesion: Bonds strongly to surfaces and retains this property over time.
-
Flexibility and Durability: Offers elasticity against structural movements and resists expansion differences.
-
UV and Temperature Protection: Colored minerals protect against UV rays, high and low temperatures, extending the membrane’s lifespan.
-
Economical and Durable: With proper application, provides reliable performance throughout the building’s lifetime.
-
Practical Application: Can be applied quickly with a blowtorch and cut to desired sizes using special cutting knives.
Areas of Use – SİM Quickshingle Rectangular (Square)
-
Wooden, reinforced concrete, and metal roofs
-
Non-accessible terraces and garden roofs
-
Domed and vaulted roofs
-
Pergolas and garden sheds
-
Canopies
-
Challenging details such as chimney bases, parapet upturns, gutters, concealed channels, and expansion joints
SİM Quickshingle Rectangular (Square) (Patterned Membrane) is used as a final-layer covering material in various applications, offering both economical and aesthetic solutions.
Packaging – SİM Quickshingle Rectangular (Square)
-
Dimensions: 1 m width × 10 m length
-
Roll Weight: Approximately 40 kg
-
Pallet Content: 1 pallet = 23 rolls
Storage
-
Bituminous membranes should be stored vertically in enclosed areas.
-
Pallets should be placed in a single layer and must not be stacked.
-
Protect from ultraviolet rays and sudden temperature changes.
Application
-
Apply at temperatures of +5°C and above, on dry, rain-free surfaces.
-
Surfaces must be smooth, even, and free from contaminants such as oil or diesel that may damage waterproofing.
-
Reinforced concrete surfaces should be primed with SİM Primer and membranes applied after the primer has dried.
-
All membrane layers should be laid in the same direction; transverse joints of the first layer should be staggered, and the second layer should be centered over the longitudinal and transverse joints of the first layer.
-
Apply the bituminous membrane using a blowtorch; transverse overlaps should be 10 cm, and longitudinal overlaps 15 cm.
Approvals / Standards
-
CE marking in compliance with TS EN 13707 standard.
Technical Data – SİM Quickshingle Rectangular (Square)
| Test | Method | Classification | Declared Value | Unit | Tolerance |
|---|---|---|---|---|---|
| Visual Defects | EN 1850-1 | – | No visual defects | – | No visual defects |
| Length | EN 1848-1 | – | 10 | m | min (-0.03) |
| Width | EN 1848-1 | – | 1 | m | min (-0.02) |
| Thickness | EN 1849-1 | – | 3.5 | mm | ±0.2 |
| Watertightness | EN 1928 (Method B, 10 kPa) | – | Passed | kPa | Passed |
| Flexibility at Low Temperature | EN 1109 | – | -5 | °C | max |
| Tensile Strength (Transverse) | EN 12311-1 | – | 400 | N/50 mm | -10% / +50% |
| Tensile Strength (Longitudinal) | EN 12311-1 | – | 600 | N/50 mm | -10% / +50% |
| Elongation at Break (Transverse) | EN 12311-1 | – | 30 | % | -5 / +20 |
| Elongation at Break (Longitudinal) | EN 12311-1 | – | 30 | % | -5 / +20 |
| Flow Resistance at High Temperature | EN 1110 | – | 110 | °C | min |
| Straightness Deviation | EN 1848-1 | – | 20 | mm | max |
| Resistance to Static Load | EN 12730 | – | 10 | kg | max |
| Granule Adhesion | EN 12039 | – | 20 | % | 0 / -30 |
| Impact Resistance | EN 12691 | – | 600 | mm | max |
| Tear Resistance (Transverse) | EN 12310-1 | – | 200 | N | ±50% |
| Tear Resistance (Longitudinal) | EN 12310-1 | – | 200 | N | ±50% |
| Joint Shear Resistance | EN 12317-1 | – | 300 | N/50 mm | ±50% |
| Reaction to Fire | EN 13501-1 | – | E | – | E |
| External Fire Performance | EN 13501-1 | – | B ROOF | – | B ROOF |
| Dangerous Substances | – | – | – | – | None |
| Watertightness After Stability Test | EN 1296 – EN 1928 | – | Passed | °C | Passed |